Handling a "Load Config" Error in Xilica Designer
If you encounter a "Load Config" error when trying to go online with your system, try these troubleshooting steps:
Check Physical Connections
Test and/or replace the network cables between your computer and the Xilica device
Ensure all connections are secure
Verify Sample Rate Settings
Look for sample rate mismatches between components
For example, if the Dante card is set to 96k in Dante Controller, but your FR1 and project file are at 48k, this will cause a Load Config error
Confirm Device Names Match
Ensure the DSP block name in your project file (.pjxml) matches exactly with the unit name in Network View
To edit the device name, double-click the device in Network View and update it in Device Setup
If these steps don't resolve the issue:
Reboot the hardware
Restart Xilica Designer
Try loading a blank project file to the device as a test
If the blank project loads successfully, your original project file may be corrupted